Heating & Air Conditioning Expert with 25 years of experience

Mon-Fri: 8am - 7pm

24h Emergency Service w/ Comfort Club Membership

Call Today (346) 326-2665

Santa Fe, TX

Rosharon TX Air Conditioning Heating

SouthCoast is proud to provide consistent five-star air conditioning and heating services throughout Rosharon, TX.

See how we make our customers’ day in our Rosharon, TX air conditioning and heating reviews below with our on-time repairs, replacements, and tune-ups.

Local Reviews
for Rosharon, TX

SouthCoast Heat & Air Rated 5.0 out of 5 stars based on 1 customer reviews


Map of Rosharon, TX

Great Service




Review of SouthCoast Heat & Air

Alex Tobey was extremely knowledgeable and patient. We are still waiting on the actual amount.


Joseph S.

Joseph S.

Diagnosed both 2 Ton Lennox & 3 Ton Lennox Furnaces and found blower motors were no longer working, ordered parts and will perform installation of 2 new blower motors.

Near Savannah Bend Ln, Rosharon, TX 77583
Joseph S.

Joseph S.

Diagnosed both 2 Ton Lennox & 3 Ton Lennox Furnaces and found blower motors were no longer working, ordered parts and will perform installation of 2 new blower motors.

Near Savannah Bend Ln, Rosharon, TX 77583
Alex T.

Alex T.

AC Repair: Found the system low on refrigerant and the dual run capacitor out of range. Recommend replacing the capacitor and charging the system with freon. Also recommend performing a leak search to find source of leak. Charged the system with 4 lbs. Of R22 refrigerant. Found leak in the condensing unit. Replaced dual run capacitor on condenser. Recommend upgrading equipment to R410A due to the age, condition and leak on the system.

Near Edward Ln, Rosharon, TX 77583
Alex T.

Alex T.

AC Repair: There is no thermostat installed for the downstairs unit, the wire to the thermostat has receded into the wall and will need to be fished out. Recommend fishing the wire out of the wall and installing new thermostat for the downstairs unit. Both filters were dirty. The disconnects for servicing the outside equipment have been bypassed. Recommend replacing service disconnects to allow proper servicing and maintenance of the outdoor equipment. Cleaned condensers and evaporators with chemicals, replaced service disconnects for outdoor units, and installed thermostat for downstairs unit. Power was turned off to the home while installing the thermostat, so we could not test the operation of the downstairs unit with the new thermostat in place.

Near Flower Grove Ct, Rosharon, TX 77583
Alex T.

Alex T.

Maintenance: Heater is operating normally at this time.

Near Creekmill Ct, Rosharon, TX 77583
Alex T.

Alex T.

AC Repair: There is no thermostat installed for the downstairs unit, the wire to the thermostat has receded into the wall and will need to be fished out. Recommend fishing the wire out of the wall and installing new thermostat for the downstairs unit. Both filters were dirty. The disconnects for servicing the outside equipment have been bypassed. Recommend replacing service disconnects to allow proper servicing and maintenance of the outdoor equipment. The gas to the home is shut off could only test part of the heating as there was no gas to provide flame.

Near Flower Grove Ct, Rosharon, TX 77583
Alex T.

Alex T.

Heater is operating normally at this time. Drain lines are clear and draining normally.

Near Broad Oaks Ln, Rosharon, TX 77583
Alex T.

Alex T.

AC Repair: Low voltage wires at the air handler are charred and low voltage fuse is tripped. Recommend repairing the wires and replacing the fuse. Thermostat is set to conventional instead of heat pump. Heat side of AC is running instead of AC.

Near Grand Spark Dr, Rosharon, TX 77583
Joseph S.

Joseph S.

Cut drywall and remove existing ductwork, keep existing register boxes, replace all ductwork throughout home.

Near Des Moines Ct, Rosharon, TX 77583
Alex T.

Alex T.

Upon arrival condensing unit was cycling on and off. System was short cycling due to a low pressure trip. Blower motor was not spinning when the system was calling for cool. Turned unit off and waited for 5 minutes. Turned unit back on and blower spun up normally. Possibly caused by a glitch or fault on the control board or blower board. System is operating. Normally at this time. Refrigerant pressures are in range. System is achieving 18° temperature split.

Near Creekmill Ct, Rosharon, TX 77583